Delivery range Formats and packets
|
strength
[mm] |
format
[mm] |
piece/
palett |
Area/
palett [m²] |
weight/
palett [kg] |
|
40 |
1200 x 675 |
100 |
81,00 |
app. 430 |
|
60 |
1200 x 675 |
66 |
53,46 |
app. 430 |
|
80 |
1200 x 675 |
50 |
40,50 |
app. 430 |
Supplied on non-returnable pallets in the format 1,350 x 1,200 mm
Pallet height approx. 2,100 mm
Other formats and thicknesses on request
Technical Data Manufacture and monitoring in accordance with DIN EN 13 171 and German technical approval Z-23.15-1581
|
Characteristics |
Test standard |
Identification |
|
Labelling |
DIN EN 13171 |
WF – EN 13171 – T3 – CS(10/Y)50 – TR2,5 – AF15 |
|
Nominal value of heat conductivity lD |
DIN EN 13171 |
0,041 W/m*K |
|
Compression strength at 10% compression |
EN 826 |
> 50 kPa |
|
Rated value of heat conductivity l |
DIN V
4108-4 |
0,043 W/m*K |
|
Behaviour in fire
|
DIN EN 13501-1 |
E |
|
Fire resistance class |
DIN 4102 |
B 2 - normal enflamable |
|
Gross density |
EN 1602 |
app. 135 kg/m³ |
|
Water vapour diffusion resistance factor m |
EN 12667 |
1 |
|
Specific heat accumulation capacity c |
DIN EN ISO 10456 |
2100 J/kg*K |
|
Constituents |
|
Wood fibres, binding fibres, ammonium phosphate |
|
Waste disposal code |
EAK-Code |
030105 |
Kronotherm DF 50 Areas of application as per DIN 4108-10
|
Roof |
Wall |
|
DAD
DI
DZ
DEO
|
Exterior insulation of roof or ceiling, protected against the elements, insulation under coverings
dg – low loading capacity
Roof/ceiling interior insulation
dm– average loading capacity
Intermediate rafter insulation, double-layer roof, not accessible, but accessible first floor ceiling
Interior insulation of the ceiling or floor section (upperside) under stone floor with no noise insulation requirements
dg – low loading capacity
dm– average loading capacity |
WAB
WH
WI
WTR |
Exterior insulation of the wall behind cladding
dg – low loading capacity
Insulation of wood frame construction and wood panel construction
Interior insulation of the wall
dk – no loading capacity
dm– average loading capacity
Insulation of partition walls |
|